Difference between revisions of "Support:Documents:Examples:FDG with Time-varying Rate Constants"

From COMKAT wiki
Jump to navigation Jump to search
Line 224: Line 224:
  
  
 
+
Notice thus far the links (arrows) that connect the compartments have not been defined.
% make copy of model thus far
+
This has been delayed since we want to make two models: one will be the standard or reference model with time-invariant rate constants
 +
and one with the time-varying K<sub>1</sub> and k<sub>2</sub>.  To make two models, we now make a copy of what we have so far
 +
<pre>
 
cmRef = cm;
 
cmRef = cm;
 +
</pre>
  
% define rate constants
 
cm = addLink(cm, 'LSpecial', 'Cp', 'Ce',  'K1', 'kinLinearTime', {'K10', 'dK1dt'});
 
cm = addLink(cm, 'KSpecial', 'Ce', 'Junk', 'k2', 'kinLinearTime', {'k20', 'dk2dt'});
 
cm = addLink(cm, 'K',        'Ce', 'Cm',  'k3');
 
if strcmp(modelConfig, '4k'),
 
    cm = addLink(cm, 'K',        'Cm', 'Ce',  'k4');
 
end
 
  
 +
For the reference model, define the links as time-invariant
 +
<pre>
 
% define reference model with time-invariant rate constants
 
% define reference model with time-invariant rate constants
 
cmRef = addLink(cmRef, 'L',        'Cp', 'Ce',  'K10');
 
cmRef = addLink(cmRef, 'L',        'Cp', 'Ce',  'K10');
 
cmRef = addLink(cmRef, 'K',        'Ce', 'Junk', 'k20');
 
cmRef = addLink(cmRef, 'K',        'Ce', 'Junk', 'k20');
 
cmRef = addLink(cmRef, 'K',        'Ce', 'Cm',  'k3');
 
cmRef = addLink(cmRef, 'K',        'Ce', 'Cm',  'k3');
if strcmp(modelConfig, '4k'),
+
cmRef = addLink(cmRef, 'K',        'Cm', 'Ce',  'k4');
    cmRef = addLink(cmRef, 'K',        'Cm', 'Ce',  'k4');
+
</pre>
end
 
  
  
% solve both models and compare outputs
+
For the fancy model, define the links with the time-varying K<sub>1</sub> and k<sub>2</sub> rate constants
 +
<pre>
 +
cm = addLink(cm, 'LSpecial', 'Cp', 'Ce',  'K1', 'kinLinearTime', {'K10', 'dK1dt'});
 +
cm = addLink(cm, 'KSpecial', 'Ce', 'Junk', 'k2', 'kinLinearTime', {'k20', 'dk2dt'});
 +
</pre>
 +
 
 +
noting that these make use of the kinLinearTime.m function defined above.
 +
 
 +
Also, define the time-invariant links
 +
<pre>
 +
cm = addLink(cm, 'K',        'Ce', 'Cm',  'k3');
 +
cm = addLink(cm, 'K',        'Cm', 'Ce',  'k4');
 +
</pre>
 +
 
 +
 
 +
OK, the models are ready for use.  Begin by solving the model to obtain the time-courses of FDG activity that these models predict would be observed in PET images.
 +
<pre>
 
[PET, PETIndex] = solve(cm);
 
[PET, PETIndex] = solve(cm);
 
[PETRef, PETRefIndex] = solve(cmRef);
 
[PETRef, PETRefIndex] = solve(cmRef);
 +
</pre>
  
 +
 +
Now plot the time-courses.  Column 1 of PET (and PETRef) holds the frame start and end times.  For convenience, compute the mid-frame time
 +
<pre>
 
tmid = (PET(:,1) + PET(:,2)) / 2;
 
tmid = (PET(:,1) + PET(:,2)) / 2;
 +
</pre>
 +
 +
And finally do the plotting
 +
<pre>
 +
plot(tmid, PET(:,3), 'b', tmid, PETRef(:,3), 'b:');
 +
xlabel('Time (Minutes)');
 +
ylabel('Activity (uCi/ml)');
 +
legend('Time-varying', 'Reference', 'Location', 'SouthEast');
 +
</pre>
  
figure
+
 
 +
Well, we can get a bit fancy and plot the time-courses of the K<sub>1</sub> and k<sub>2</sub> rate constants above the model outputs and add other annotations.
 +
<pre>
 
clf
 
clf
 
axK1k2 = axes('position', [0.2 0.75 0.7 0.2]);
 
axK1k2 = axes('position', [0.2 0.75 0.7 0.2]);
Line 269: Line 297:
 
ylabel('Activity (uCi/ml)');
 
ylabel('Activity (uCi/ml)');
 
legend('Time-varying', 'Reference', 'Location', 'SouthEast');
 
legend('Time-varying', 'Reference', 'Location', 'SouthEast');
 
 
% What would be the value of rate constants estimated while neglecting the time-variation?
 
% Fit the time-invariant model to the time-varying model data.
 
data = PET(:,3);
 
cmRef = set(cmRef, 'ExperimentalData', data);
 
pinit = [0.07; 0.1;  0.04;  0.005];
 
plb =  [0.01; 0.001; 0.001; 0.0001];
 
pub =  [0.5;  0.5;  0.2;  0.01];
 
if strcmp(modelConfig, '4k'),
 
    cmRef = addSensitivity(cmRef, 'K10', 'k20', 'k3', 'k4');
 
else
 
    cmRef = addSensitivity(cmRef, 'K10', 'k20', 'k3');
 
    pinit(4) = [];
 
    plb(4) = [];
 
    pub(4) = [];
 
end
 
 
[pfit, modelFit] = fit(cmRef, pinit, plb, pub);
 
 
 
 
figure
 
phFit = plot(tmid, data, 'bo', tmid, modelFit, 'b:');
 
set(phFit, 'LineWidth', 1.5);
 
ax = axis; ax(3) = 0; axis(ax);
 
xlabel('Time (Minutes)');
 
ylabel('Activity (uCi/ml)');
 
 
KiRange = [K10*k3/(k20 + k3); (K10 + dK1dt)*k3/(k20 + k3); K10*k3/((k20 + dk2dt) + k3); (K10 + dK1dt)*k3/((k20 + dk2dt) + k3)];   
 
KiInit = K10*k3/(k20 + k3);
 
if strcmp(modelConfig, '4k'),
 
    c = {'Parm.', 'True', 'Est', 'vs. Init', 'Units'; ...
 
        'K1', sprintf('%1.3f -> %1.3f', K10, K10 + dK1dt * PET(end,2)), sprintf('%1.3f', pfit(1)), sprintf('%1.1f%%', 100*(pfit(1)-K10)/K10), '1/min';
 
        'k2', sprintf('%1.3f -> %1.3f', k20, k20 + dk2dt * PET(end,2)), sprintf('%1.3f', pfit(2)), sprintf('%1.1f%%', 100*(pfit(2)-k20)/k20), '1/min';
 
        'k3', sprintf('%1.3f', k3),                                    sprintf('%1.3f', pfit(3)), sprintf('%1.1f%%', 100*(pfit(3)-k3)/k3),  '1/min';
 
        'k4', sprintf('%1.3f', k4),                                    sprintf('%1.3f', pfit(4)), sprintf('%1.1f%%', 100*(pfit(4)-k4)/k4),  '1/min';
 
        'Ki', sprintf('%1.3f - %1.3f', min(KiRange), max(KiRange)),    sprintf('%1.3f', pfit(1)*pfit(3)/(pfit(2)+pfit(3))), sprintf('%1.1f%%', 100*(pfit(1)*pfit(3)/(pfit(2)+pfit(3))-KiInit)/KiInit), '1/min';
 
      };
 
else
 
    c = {'Parm.', 'True', 'Est', 'vs. Init', 'Units'; ...
 
        'K1', sprintf('%1.3f -> %1.3f', K10, K10 + dK1dt * PET(end,2)), sprintf('%1.3f', pfit(1)), sprintf('%1.1f%%', 100*(pfit(1)-K10)/K10), '1/min';
 
        'k2', sprintf('%1.3f -> %1.3f', k20, k20 + dk2dt * PET(end,2)), sprintf('%1.3f', pfit(2)), sprintf('%1.1f%%', 100*(pfit(2)-k20)/k20), '1/min';
 
        'k3', sprintf('%1.3f', k3),                                    sprintf('%1.3f', pfit(3)), sprintf('%1.1f%%', 100*(pfit(3)-k3)/k3),  '1/min';
 
        'Ki', sprintf('%1.3f - %1.3f', min(KiRange), max(KiRange)),    sprintf('%1.3f', pfit(1)*pfit(3)/(pfit(2)+pfit(3))), sprintf('%1.1f%%', 100*(pfit(1)*pfit(3)/(pfit(2)+pfit(3))-KiInit)/KiInit), '1/min';
 
      };
 
end
 
   
 
table(c, [0.4, 0.3] );
 
legend('Time-varying Data', 'Time-invariant Fit', 'Location', 'SouthEast');
 
 
 
 
</pre>
 
</pre>
  
First create an new model stored in variable bfcm (blood flow compartment model) and add compartments.
+
[[Image:ExampleFigureFDGTimeVaryingK1k2.png]]
The J compartment is not shown in the figure above but is needed to accept the flux from the k<sub>2</sub> arrow.
 
<pre>
 
% create new, empty model
 
bfcm = compartmentModel;
 
 
% add compartments
 
bfcm = addCompartment(bfcm, 'CT');
 
bfcm = addCompartment(bfcm, 'J');
 
</pre>
 
  
  
==== Specify the input ====
 
The specific activity (ratio of activity to molar concentration) is an exponentially decaying function S(t) = S<sub>0</sub> exp(-0.341 t) where t is expressed in units of minutes and 0.341 = ln(2)/half-life of <sup>15</sup>O and S<sub>0</sub> is the specific activity at time t = 0.
 
<pre>
 
% define the initial specific activity and decay constant
 
sa0 = 1; % specific activity at t=0
 
dk = 0.341; % O-15 decay constant
 
</pre>
 
  
 +
Well, now I'm wondering what happens if someone fits the standard (time-invariant rate constants) model to data wherein the
 +
the physiology (rate constants) are changing?  Lets use the models to find out.  Use the fancy model to create "data" and fit the standard model to that "data".
  
Next specify the input functions C<sub>p</sub> and C<sub>a</sub> for the compartment model.  fin is the name of the function that implements Feng input.  pCp and pCa are parameter vectors that hold the values of p<sub>1</sub>, p<sub>2</sub>, ... p<sub>6</sub> for C<sub>p</sub> and C<sub>a</sub>.
 
 
<pre>
 
<pre>
bfcm = addInput(bfcm, 'Cp', sa0, dk, 'fin', 'pCp');
+
data = PET(:,3);
bfcm = addParameter(bfcm, 'pCp', 2*[851.1 21.88 20.81 -4.134 -0.1191 -0.01043 .5]);
+
cmRef = set(cmRef, 'ExperimentalData', data);
 
 
bfcm = addInput(bfcm, 'Ca', sa0, dk, 'fin', 'pCa');
 
bfcm = addParameter(bfcm, 'pCa', [851.1 21.88 20.81 -4.134 -0.1191 -0.01043 .5]);
 
 
</pre>
 
</pre>
  
  
Define the connections (arrows) between the compartment and input.  The link type 'L' indicates linear kinetics from an input to a compartment and type 'K' indicates linear kinetics from one compartment to another. 
+
Set the initial guess and lower and upper bounds on the rate constants
 
<pre>
 
<pre>
% connect compartments and inputs
+
pinit = [0.07; 0.1;  0.04;  0.005]; % inital guess
bfcm = addLink(bfcm, 'L', 'Cp', 'CT', 'K1');
+
plb =   [0.01; 0.001; 0.001; 0.0001]; % lower bound
bfcm = addLink(bfcm, 'K', 'CT', 'J', 'k2');
+
pub =   [0.50.5;  0.2;  0.01]; % upper bound
   
+
cmRef = addSensitivity(cmRef, 'K10', 'k20', 'k3', 'k4');
% define values for K1, k2 ...
 
bfcm = addParameter(bfcm, 'K1', 'F');
 
bfcm = addParameter(bfcm, 'k2', 'K1/lambda');
 
bfcm = addParameter(bfcm, 'F', 0.5);
 
bfcm = addParameter(bfcm, 'lambda', 1.0);
 
bfcm = addParameter(bfcm, 'Fv', 0.05);
 
 
</pre>
 
</pre>
  
 
+
Now do the fitting
==== Define tissue and blood outputs ====
 
Define two model outputs.  The output called TissuePixel predicts the activity in a tissue pixel and the output called ArterialPixel predicts the activity that would be observed in a pixel in the aorta.  TissuePixel corresponds to C<sub>T</sub>S + F<sub>v</sub>C<sub>a</sub> whereas ArterialPixel is 100% C<sub>a</sub>.
 
 
<pre>
 
<pre>
% define the activity concentration in tissue pixel
+
[pfit, modelFit] = fit(cmRef, pinit, plb, pub);
bfcm = addOutput(bfcm, 'TissuePixel', {'CT', '1'}, {'Ca', 'Fv'});
 
 
% define the activity concentration in arterial blood pixel
 
bfcm = addOutput(bfcm, 'ArterialPixel', {'CT', '0'}, {'Ca', '1'});
 
</pre>
 
 
 
Note that COMKAT even accounts for the time-averaging of concentrations over the durations of the scan frames.
 
For simplicity here a sequence of contiguous 10-second frames is used.  (Frame start times 0, 10, 20, ... 590 sec and frame end times 10, 20, 30, ... 600 sec).
 
<pre>
 
% specify scan frame times
 
bfcm = set(bfcm, 'ScanTime', [[0:10:590]' [10:10:600]']/60); % division by 60 converts sec to min
 
 
</pre>
 
</pre>
  
  
==== Solve for the model output ====
+
Plot the fit over the "data"
Finally, tell COMKAT to solve the model to obtain simulation data that will be used in fitting.
 
 
<pre>
 
<pre>
[PET, PETIndex, Output, OutputIndex] = solve(bfcm);
+
figure
 
+
phFit = plot(tmid, data, 'bo', tmid, modelFit, 'b:');
% plot activity in tissue PET(:,3) and blood PET(:,4)
+
set(phFit, 'LineWidth', 1.5);
midTime = (PET(:,1) + PET(:,2)) / 2;
+
ax = axis; ax(3) = 0; axis(ax);
plot(midTime, PET(:,3), 'b-', midTime, PET(:,4), 'r.')
+
xlabel('Time (Minutes)');
legend(PETIndex{3}, PETIndex{4})
+
ylabel('Activity (uCi/ml)');
 
+
legend('Time-varying Data', 'Time-invariant Fit', 'Location', 'SouthEast');
% make the figure for this wiki
 
set(1,'PaperPosition',[0.25 2.5 3 2])
 
print -dpng c:\temp\ExampleFigureBloodFlowInputModelDataToFit.png
 
</pre>
 
 
 
Note, different rows of PET correspond to different frames.  The columns of PET hold various quantities as indicated in PETIndex.  That is, the contents of column i are described in PETIndex{i}.
 
 
 
[[Image:ExampleFigureBloodFlowInputModelDataToFit.png]]
 
 
 
 
 
== Fit Data ==
 
Modify the COMKAT model a bit so that it can be used to fit data created above.
 
 
 
==== Specify the data to fit ====
 
Just use the result from above.
 
<pre>
 
data = PET(:, [3 4]);
 
bfcm = set(bfcm, 'ExperimentalData', data);
 
 
</pre>
 
</pre>
 +
 
  
Specify parameters to estimate along with their initial guesses and range of feasible values.
+
[[Image:ExampleFigureFDGTimeVaryingK1k2Fit.png]]
<pre>
 
% specify parameters to estimate
 
bfcm = addSensitivity(bfcm, 'pCp', 'F');
 
  
% define initial guess and lower and upper bounds
 
pCpInit = 0.9*2*[851.1 21.88 20.81 -4.134 -0.1191 -0.01043 .5];
 
FInit = 0.3;
 
pinit = [pCpInit FInit];
 
lb = [2*[85 2 2 -8 -3 -0.1 .05] 0.1];
 
ub = [2*[2000 100 200 -1 -0.01 -0.001 2] 1.];
 
</pre>
 
 
 
Note the values of the initial guesses for the input function parameters are 0.9 times the true values.  (We're are not cheating by starting with the correct values.)
 
 
 
==== Do the actual fitting ====
 
Fit the data to estimate values of the parameters
 
<pre>
 
[pEst, modelFit] = fit(bfcm, pInit, lb,ub);
 
</pre>
 
COMKAT makes fitting easy!
 
 
 
Plot the results and make the figure below for this wiki
 
<pre>
 
plot(midTime, modelFit(:,1), 'b', midTime, PET(:,3), 'b.', midTime, modelFit(:,2), 'r', midTime, PET(:,4), 'r.')
 
legend('Tissue Fit', PETIndex{3}, 'Arterial Fit', PETIndex{4})
 
xlabel('Time')
 
ylabel('Activity')
 
print -dpng c:\temp\ExampleFigureBloodFlowInputModelFit.png
 
</pre>
 
  
[[Image:ExampleFigureBloodFlowInputModelFit.png]]
 
  
====Ta Da====
+
'''Note'''  This code for this example can be found in frgTimeVarying.m in the COMKAT examples folder.  That version has a few extra bells and whistles that allow us, for example. to use the FDG model with or without k<sub>4</sub>.
It looks like a pretty good fit.
 

Revision as of 00:17, 28 March 2008

FDG Model with Time-varying Rate Constants

Overview

This example demonstrates how to implement the two-tissue compartment model with extended such that K1 and k2 vary in time.

This models the case where there are physiologic changes during the course of the PET scanning. This might happen if tumors are being treated during scanning.

The standard FDG model was described by Phelps and Huang .

ExampleFigureFDGModel.png


It can also be described by the differential equations:

dCe/dt = K1 Cp - k2 Ce - k3 Ce + k4 Cm

dCm/dt = k3 Ce - k4 Cm


Ce is the tissue concentration of FDG and Cm as the tissue concentration of metabolized FDG (FDG-6-phosphate)

Ce and Cm are interpreted as molar concentrations (Salinas, Muzic and Saidel 2007).


In the standard model. the rate constants K1, k2, k3 and k4 are assumed to be independent of time.


Here we allow K1 and k2 to be linear functions of time:

K1(t) = K10 + a t

k2(t) = K20 + b t

a and b are the derivatives (slopes) of the rate constant with respect to time.


To implement the time-varying rate constants, we create a MATLAB function in a .m file. By making the function general, the same function can be used for K1 and k2.

function varargout = kinLinearTime(t, c, ncomp, nsens, pName, pValue, pSensIdx, cm, xtra)
% rate constant varies linearly with time: k = k0 + m*t  where m = dk/dt

K0Name = pName{1};
dkdtName = pName{2};
K0Value = pValue{1};
dkdtValue = pValue{2};
K0SensIndex = pSensIdx{1};
dkdtSensIndex = pSensIdx{2};

if (nargout > 0), % return effective rate constant
    v = K0Value + dkdtValue * t;
    if (v < 0), % don't allow negative values for rate constant
        varargout{1} = 0;
    else
        varargout{1} = v;
    end        
    if (nargout > 1),  % return dk/dc 
        dkdc = zeros([1 ncomp]); 
        varargout{2} = dkdc;  
        if (nargout > 2), % return dk/dp
            dkdp = zeros([1 nsens]);
            if (v >= 0),
                dkdp(K0SensIndex) = 1;
                dkdp(dkdtSensIndex) = t;
            end        
            varargout{3} = dkdp; % dkdp
            if (nargout > 3),
                ddkdpdc = zeros([ncomp nsens]);
                varargout{4} = ddkdpdc; % ddkdpdc
            end
        end
    end
end
return


This function is pretty straightforward. The emphasis of our description here is on the mathematical aspects. The first output argument varargout{1} holds the value of the rate constant specified at the current time t. This value is first calculated and stored in the variable v.

v = K0Value + dkdtValue * t

k0 is the rate constant at time zero (t=0) and dkdtValue is the increase in the rate constant per unit time (time-derivative or slope). k0Value and dkdtValue are the MATLAB variables that hold the values of these parameters. The value of v is checked to see if it is negative and, if it is, the value zero is used instead since negative values for rate constants are non-physiologic.

The line

varargout{2} = dkdc;  

returns the derivative of the rate constant with respect to all the compartment concentrations (a vector). In this case, the rate constant is not dependent on the concentrations so the derivatives are all zeros.


The lines

dkdp(K0SensIndex) = 1;
dkdp(dkdtSensIndex) = t;

calculate the derivatives of the rate constant with respect to the model parameters k0 (the initial value of the rate constant) and dkdt (the increase in k per unit time). Since a model can have other parameters besides these, the function stores these derivatives in the appropriate element of the derivative vector. Derivatives of this rate constant with respect to all other parameters are zeros.


The line

varargout{4} = ddkdpdc; % ddkdpdc

returns the values of the mixed derivatives (derivative of rate constant with respect to concentrations and with respect to time), which, in this case are all zeros.

The function is stored in kinLinearTime.m in the comkat examples folder.

This function is called to evaluate both K1 and k2.


Implementing the Compartment Model

Create a new model

First define some MATLAB variables for clarity and to facilitate exploring what happens if values are changed

K10 =  0.15;  % K1 = K10 + dK1dt * t
dK1dt = -K10 * 0.5 / 60;  % 50% decrease per 60 minutes
k20 =  0.325; % k2 = k20 + dk2dt * t
dk2dt = -k20 * 0.5 / 60;  % 50% decrease per 60 minutes
k3 = 0.05;
k4 = 0.007;


Next, create a compartment model object and define the parameters within the model object

% create empty compartmentModel object
cm = compartmentModel;
  
% define the parameters
cm = addParameter(cm, 'K10',   K10);    % 1/min
cm = addParameter(cm, 'k20',   k20);    % 1/min
cm = addParameter(cm, 'k3',    k3);     % 1/min
cm = addParameter(cm, 'k4',    k4);     % 1/min
cm = addParameter(cm, 'dK1dt', dK1dt);  % 1/min/min
cm = addParameter(cm, 'dk2dt', dk2dt);  % 1/min/min

cm = addParameter(cm, 'sa',    1);            % specific activity of injection
cm = addParameter(cm, 'dk',    log(2)/109.8); % F-18 radioactive decay
cm = addParameter(cm, 'PV',    1);            % (none)


Now, define the model compartments. The first two are Ce and Cm as described above and Junk is a "sink" that collects the FDG that is cleared by the venous circulation.

cm = addCompartment(cm, 'Ce');
cm = addCompartment(cm, 'Cm');
cm = addCompartment(cm, 'Junk');


For the plasma concentration time-course of FDG or input function, we'll use the Feng input which is an analytic expression. Since piecewise polynomials (linear interpolation, cubic splines, etc...) are widely used in COMKAT and their implementation has been optimized, here we construct a cubic spline representation of the input function by sampling the Feng input.

x0=[2 0.5 16.000 2.188 2.081 -7.5 -10 -0.01043]; % Feng parameters
t = [0:.1:3 3.5 4 4.5 5:1:10 12 15:5:(expDuration+5)];
Cp = fengInput(x0, t);
ppCp = spline(t, Cp);
cm = addInput(cm, 'Cp', 'sa', 'dk', 'ppval', ppCp);  % Cp has units of pmol/ml


The PET scanner measurement is assumed to represent the sum of FDG and FDG-6-Phosphate so the model output is calculated as the sum of the Ce and Cm compartments

Wlist = {...
    'Ce', 'PV';
    'Cm', 'PV'};
Xlist = {};
cm = addOutput(cm, 'PET', Wlist, Xlist);


Next define the scan frames as the start and stop time of each image in the dynamic sequence.

ttt=[ ones(12,1)*10/60; ...  % 10 sec
      ones(10,1)*0.5; ...    %  0.5 min
      ones(10,1)*2;...       %  2 min
      ones(10,1)*5;...       %  5 min
      ones(4,1)*10];         % 10 min
scant=[[0;cumsum(ttt(1:(length(ttt)-1)))] cumsum(ttt)];
cm = set(cm, 'ScanTime', scant);

Note the acquisition begins with 12 frames of 10 sec duration, then has 10 frames of 0.5 minute duration, etc... The cumsum() function calculates the cumulative summation. Thus, the first column of scant holds the scan start times and the second column holds the scan end times. These are expressed in minutes:

scant =

         0    0.1667
    0.1667    0.3333
    0.3333    0.5000
    0.5000    0.6667
    0.6667    0.8333
    0.8333    1.0000
    1.0000    1.1667
    1.1667    1.3333
    1.3333    1.5000
    1.5000    1.6667
    1.6667    1.8333
    1.8333    2.0000
...


Notice thus far the links (arrows) that connect the compartments have not been defined. This has been delayed since we want to make two models: one will be the standard or reference model with time-invariant rate constants and one with the time-varying K1 and k2. To make two models, we now make a copy of what we have so far

cmRef = cm;


For the reference model, define the links as time-invariant

% define reference model with time-invariant rate constants
cmRef = addLink(cmRef, 'L',        'Cp', 'Ce',   'K10');
cmRef = addLink(cmRef, 'K',        'Ce', 'Junk', 'k20');
cmRef = addLink(cmRef, 'K',        'Ce', 'Cm',   'k3');
cmRef = addLink(cmRef, 'K',        'Cm', 'Ce',   'k4');


For the fancy model, define the links with the time-varying K1 and k2 rate constants

cm = addLink(cm, 'LSpecial', 'Cp', 'Ce',   'K1', 'kinLinearTime', {'K10', 'dK1dt'});
cm = addLink(cm, 'KSpecial', 'Ce', 'Junk', 'k2', 'kinLinearTime', {'k20', 'dk2dt'});

noting that these make use of the kinLinearTime.m function defined above.

Also, define the time-invariant links

cm = addLink(cm, 'K',        'Ce', 'Cm',   'k3');
cm = addLink(cm, 'K',        'Cm', 'Ce',   'k4');


OK, the models are ready for use. Begin by solving the model to obtain the time-courses of FDG activity that these models predict would be observed in PET images.

[PET, PETIndex] = solve(cm);
[PETRef, PETRefIndex] = solve(cmRef);


Now plot the time-courses. Column 1 of PET (and PETRef) holds the frame start and end times. For convenience, compute the mid-frame time

tmid = (PET(:,1) + PET(:,2)) / 2;

And finally do the plotting

plot(tmid, PET(:,3), 'b', tmid, PETRef(:,3), 'b:');
xlabel('Time (Minutes)');
ylabel('Activity (uCi/ml)');
legend('Time-varying', 'Reference', 'Location', 'SouthEast');


Well, we can get a bit fancy and plot the time-courses of the K1 and k2 rate constants above the model outputs and add other annotations.

clf
axK1k2 = axes('position', [0.2 0.75 0.7 0.2]);
phK = plot(axK1k2, tmid, K10 + dK1dt * tmid, 'b', tmid, k20 + dk2dt * tmid,  'r', ...
             tmid, K10 + 0 * tmid, 'b:',                tmid, k20 + 0 * tmid, 'r:');
set(phK, 'LineWidth', 1.5);
ax = axis; ax(3) = 0; ax(4) = 0.5; axis(ax);
ylabel('Rate Const. (1/min)');
lh = legend('K1', 'k2', 'K1', 'k2', 'Location', 'SouthEast');
set(lh, 'fontsize', 8);

axPET = axes('position', [0.2 0.2 0.7 0.4]);
phPET = plot(axPET, tmid, PET(:,3), 'b', tmid, PETRef(:,3), 'b:');
set(phPET, 'LineWidth', 1.5);
ax = axis; ax(3) = 0; axis(ax);
xlabel('Time (Minutes)');
ylabel('Activity (uCi/ml)');
legend('Time-varying', 'Reference', 'Location', 'SouthEast');

ExampleFigureFDGTimeVaryingK1k2.png


Well, now I'm wondering what happens if someone fits the standard (time-invariant rate constants) model to data wherein the the physiology (rate constants) are changing? Lets use the models to find out. Use the fancy model to create "data" and fit the standard model to that "data".

data = PET(:,3);
cmRef = set(cmRef, 'ExperimentalData', data);


Set the initial guess and lower and upper bounds on the rate constants

pinit = [0.07; 0.1;   0.04;  0.005]; % inital guess
plb =   [0.01; 0.001; 0.001; 0.0001];  % lower bound
pub =   [0.5;  0.5;   0.2;   0.01]; % upper bound
cmRef = addSensitivity(cmRef, 'K10', 'k20', 'k3', 'k4');

Now do the fitting

[pfit, modelFit] = fit(cmRef, pinit, plb, pub);


Plot the fit over the "data"

figure
phFit = plot(tmid, data, 'bo', tmid, modelFit, 'b:');
set(phFit, 'LineWidth', 1.5);
ax = axis; ax(3) = 0; axis(ax);
xlabel('Time (Minutes)');
ylabel('Activity (uCi/ml)');
legend('Time-varying Data', 'Time-invariant Fit', 'Location', 'SouthEast');


ExampleFigureFDGTimeVaryingK1k2Fit.png


Note This code for this example can be found in frgTimeVarying.m in the COMKAT examples folder. That version has a few extra bells and whistles that allow us, for example. to use the FDG model with or without k4.